FMEA Diagnostic Intelligence
Prototype · Factory Booster Day · Challenge #86
Structured knowledge

FMEA knowledge base

Aggregated failure modes with historical frequency and confidence. Replaces the static spreadsheet.

SymptomComponentParameterRoot causeSolutionFreqConfidenceLast updateOwner
High oil temperatureCooler tubesWater side clean or obstructed?ObstructionClean component11
55%
Jun 24, 2026, 08:12 AMMaint. Specialist
High oil temperatureWater supplyInlet pressure within spec?Insufficient water flowInspect water supply5
25%
May 12, 2026, 05:50 AMMaint. Specialist
Low pressurePressure valveInlet pressure within spec?Mechanical wearClean component2
40%
Jun 27, 2026, 10:00 AMMaint. Specialist
Low pressurePumpInlet pressure within spec?Mechanical wearEscalate to maintenance specialist2
40%
Jun 28, 2026, 09:00 AMOps Team
Abnormal vibrationMotorVibration RMS above threshold?Mechanical wearEscalate to maintenance specialist2
67%
Jun 26, 2026, 11:11 AMMaint. Specialist
High oil temperatureCooler tubesWater side clean or obstructed?Insufficient water flowInspect water supply1
5%
May 28, 2026, 07:45 AMMaint. Specialist
High oil temperatureTemperature sensorInstrument calibrated?Calibration issueCalibrate instrument1
5%
Apr 25, 2026, 05:20 PMMaint. Specialist
High oil temperatureTemperature sensorInstrument calibrated?Calibration issueReplace sensor1
5%
Apr 22, 2026, 06:00 AMMaint. Specialist
High oil temperatureTemperature sensorInstrument calibrated?Electrical failureReplace sensor1
5%
Apr 20, 2026, 07:35 PMMaint. Specialist
Low pressurePressure valveInlet pressure within spec?Incorrect parameter settingAdjust process parameter1
20%
Jun 08, 2026, 02:15 PMOps Team
Abnormal vibrationRobot armVibration RMS above threshold?Mechanical wearEscalate to maintenance specialist1
33%
Jun 21, 2026, 09:00 AMMaint. Specialist
Sensor failurePLC modulePLC diagnostic flag active?Electrical failureReplace sensor1
50%
Jun 23, 2026, 01:00 PMMaint. Specialist
Sensor failureTemperature sensorInstrument calibrated?Calibration issueCalibrate instrument1
50%
Jun 16, 2026, 10:00 AMMaint. Specialist
Unexpected shutdownPLC modulePLC diagnostic flag active?Electrical failureEscalate to maintenance specialist1
33%
Jun 25, 2026, 04:00 PMOps Team
Unexpected shutdownPLC modulePLC diagnostic flag active?Incorrect parameter settingAdjust process parameter1
33%
Jun 17, 2026, 08:30 AMMaint. Specialist
Unexpected shutdownMotorPLC diagnostic flag active?Electrical failureEscalate to maintenance specialist1
33%
Jun 11, 2026, 12:45 PMMaint. Specialist